◆Introduction LW30 series rotary switches applied to circuits of AC 50Hz with working voltave up to 440V and rated working current up to 100A.
LW30 is suitable to control:air-conditioner,water pump and ventilating equipments,and AC motors with small power..
LW30 series rotary switches have six current ratings:20A,25A,32A,40A,63A,80A and 100A.
LW30 series has the finger protection terminals,which offers an extra advantage.
LW30 series switches has Larger insulation distance,quick disconnectinvg response.And is a good choice For DC circuits.LW 30 has additional contact which enable us to install the contact separetely.
LW30 series rotary switches switches comply with:GB/T 14048.3,and IEC 60947-3.
◆Technical parameters
Description |
LW30-25(20) |
LW30-32 |
LW30-40 |
LW30-63 |
LW30-80 |
LW30-100 |
Rated thermal current |
ITH |
A |
25(20) |
32 |
40 |
63 |
80 |
100 |
Rated working voltage |
LE |
V |
240 |
440 |
240 |
440 |
240 |
440 |
240 |
440 |
240 |
440 |
240 |
440 |
Ie/Pe |
Ie/Pe |
|
|
|
|
|
|
|
|
|
|
|
|
|
AC-21A |
|
A/KW |
20/- |
20/- |
32/- |
32/- |
40/- |
40/- |
63/- |
63/- |
80/- |
80/- |
100/- |
100/- |
AC-22A |
|
A/KW |
20/- |
20/- |
32/- |
32/- |
40/- |
40/- |
63/- |
63/- |
80/- |
80/- |
100/- |
100/- |
AC-23A |
|
A/KW |
15/4 |
15/7.5 |
22/5.5 |
22/11 |
30/7.5 |
30/15 |
43/11 |
43/22 |
57/18.5 |
57/30 |
70/22 |
70/37 |
AC-3 |
|
A/KW |
11.7/3 |
11.7/5.5 |
15/4 |
15/7.5 |
22/7.5 |
22/11 |
36/11 |
36/18.5 |
43/15 |
57/30 |
57/18.5 |
57/30 |
◆Dimensions and installation Panel installation
Description |
Dimensions(mm)
|
Installation(mm)
|
A |
B |
C |
K |
L |
E |
F |
D1 |
D2 |
LW30-20 |
□64 |
42 |
54 |
13.5 |
61 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-25 |
□64 |
42 |
54 |
13.5 |
61 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-32 |
□64 |
42 |
54 |
13.5 |
61 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-40 |
□64 |
50 |
64 |
16 |
67 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-63 |
□64 |
50 |
64 |
16 |
67 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-80 |
□64 |
70 |
80 |
22.5 |
82 |
48 |
48 |
Φ10 |
Φ4.2 |
LW30-100 |
□64 |
70 |
80 |
22.5 |
82 |
48 |
48 |
Φ10 |
Φ4.2 |
Base installation
Description |
Dimensions(mm)
|
Installation(mm)
|
A |
B |
C |
L |
H |
E |
F |
D2 |
LW30-20 |
45 |
42 |
54 |
50 |
26 |
22 |
60 |
Φ4.2 |
LW30-25 |
45 |
42 |
54 |
50 |
26 |
22 |
60 |
Φ4.2 |
LW30-32 |
45 |
42 |
54 |
50 |
26 |
22 |
60 |
Φ4.2 |
Single hole installation
Description |
Dimensions(mm)
|
Installation(mm)
|
A |
B |
C |
L |
E |
F |
G |
LW30-20 |
□49 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
LW30-20 |
□64 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
LW30-25 |
□49 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
LW30-25 |
□64 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
LW30-32 |
□49 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
LW30-32 |
□64 |
42 |
54 |
69 |
22.3 |
24.1 |
Φ3.2 |
Installation of doorlock safety switch
Description |
Dimensions(mm) |
Installation(mm) |
K |
Lmin |
Lmax |
E |
F |
D1 |
D2 |
LW30-20 |
50 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-25 |
50 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-32 |
50 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-40 |
61 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-63 |
61 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-80 |
68 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-100 |
68 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
RE:product can be installed in 35mm parallel。
Protective cover
Description |
Dimensions(mm) |
Installation(mm) |
A |
B |
K |
Lmin |
Lmax |
E |
F |
D1 |
D2 |
LW30-80 |
70 |
133 |
68 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
LW30-100 |
70 |
133 |
68 |
32 |
150 |
48 |
48 |
Φ22 |
Φ4.2 |
Plastic box
Description |
Dimensions(mm) |
Installation(mm) |
D3 |
D4 |
M |
N |
P |
A1 |
A2 |
B |
D2 |
LW30-20 |
Φ23 |
Φ19 |
85 |
83 |
160 |
150 |
-- |
-- |
Φ4.2 |
LW30-25 |
Φ23 |
Φ19 |
85 |
83 |
160 |
150 |
-- |
-- |
Φ4.2 |
LW30-32 |
Φ23 |
Φ19 |
85 |
83 |
160 |
150 |
-- |
-- |
Φ4.2 |
LW30-40 |
Φ29 |
Φ23 |
100 |
95 |
190 |
178 |
-- |
-- |
Φ4.2 |
LW30-63 |
Φ29 |
Φ23 |
100 |
95 |
190 |
178 |
-- |
-- |
Φ4.2 |
LW30-80 |
Φ37.5 |
Φ23 |
144 |
105 |
250 |
-- |
229 |
124 |
Φ6.5 |
LW30-100 |
Φ37.5 |
Φ23 |
144 |
105 |
250 |
-- |
229 |
124 |
Φ6.5 |